4. SPECIFICATIONS
4.1 Electrical Specifications
Product Name Frequency (Hz) Voltage (V) Capacity VA / W
100 / 110 / 120
VS375C
50/60
220 / 230 / 240
375VA / 225W
100 / 110 / 120
VS575C
50/60
220 / 230 / 240
575VA / 345W
Input/Output Voltage
AC Line Voltage
Version Lower Limit Upper Limit
100 / 110 / 120V 85/ 94/ 102V 120 / 134 / 138V
220 / 230 / 240V 165/ 184/ 192V 275 / 276 / 276V
Input/Output Frequency Range
Input
50 Hz / 60 Hz ± 10%
Output (Inverter mode)
50 Hz / 60 Hz ± 0.3 Hz
Wave Form :
AC Mode
Sine wave
Back-Up Mode
Step wave
Transfer Time:
Power failure AC inverter
4 ms (typical)
Spike/Surge Protection:
Single pulse 8/20us
Version
Continuous
Voltage Vrms
Imax Joules
100/110/120 175V 6500A 1050
220/230/240 300V 6500A 1050
Data-Line Surge Suppression:
Telephone Line Surge Protection
+/- 6KV Peak
(1.2
µ
S/50 Waveform)
10/100 Base-T Protection Let
Through Rating
<1%
(From 6KV/125A Normal Mode Surge)